Gas Turbine General Electric 110MW MS 9001E (02)

Starting bid: $1.00

Item condition: New

Time Left:
Ending On: May 29, 2024 9:47 pm
Timezone: UTC 0

Reserve price has not been met.

Custom Bid
$
(Enter more than or equal to : $1.00 )

Two sets of MS 9001E

Click the Link below for Details

 1. General Electric 110MW MS 9001E Gas Turbine

Asset Overview 1993

  • Model :- MS 9001E
  • Turbine Rating: 123MW
  • Year of Manufacture:1993
  • Year of Starting Operation: 1994
  • Last Hot Gas Path Major Inspection: 8th Dec 2015 – 31st Dec 2015
  • Dual Fuel Type

Operational Data

  • Total Fired Hours: 174,357
  • Total Fired Starts: 2010
  • Total Emergency Stops: 199
  • Peak Fired Hours: 0
  • Total Starts:2209

Technical Specifications

  • Fuel: Gas / Liquid Fuel
  • Nominal continuous site rating: 109.5 MW
  • Operating speed: 3000 rpm
  • Number of compressor stages: 17
  • Number of turbine stages: 3
  • Compressor site pressure ratio: 10.8 bar
  • Gas turbine site exhaust temperature: 538 °C
  • Type of combustion: Multiple combustion reverse flow design (Can Type)
  • Number of combustion chambers: 14
  • Min. Natural gas pressure: 22.2 bar
  • Liquid fuel type: Distillate
  • Starting system: Starting motor

The auxiliary equipment of the gas turbine includes:

  1. Starting Equipment with an induction motor and torque converter coupled to the accessory gear.
  2. Turning Gear
  3. Lubricating Oil System with the following components:
    • Lube oil reservoir in the accessory base
    • Main lube oil pump (shaft driven from the accessory gear)
    • Auxiliary lube oil pump and emergency lube oil pump (motor driven)
    • Auxiliary seal oil pump and emergency seal oil pump (motor driven)
    • Pressure relief valve VR-1
    • Lube oil fluid heat exchangers
    • Lube oil filters
    • Bearing header pressure regulator
    • Mist eliminator
 2  .1994 General Electric 110MW MS 9001E Gas Turbine
 

Asset Overview

  • Model :- MS 9001E
  • Turbine Rating: 123MW
  • Year of Manufacture:1994
  • Year of Starting Operation: 1994
  • Last Hot Gas Path Major Inspection: 8th Dec 2015 – 2nd  Jan 2016
  • Dual Fuel Type

Operational Data

  • Total Fired Hours: 173,221
  • Total Fired Starts: 1513
  • Total Emergency Stops: 189
  • Peak Fired Hours: 0
  • Total Starts:1702

Technical Specifications

  • Fuel: Gas / Liquid Fuel
  • Nominal continuous site rating: 109.5 MW
  • Operating speed: 3000 rpm
  • Number of compressor stages: 17
  • Number of turbine stages: 3
  • Compressor site pressure ratio: 10.8 bar
  • Gas turbine site exhaust temperature: 538 °C
  • Type of combustion: Multiple combustion reverse flow design (Can Type)
  • Number of combustion chambers: 14
  • Min. Natural gas pressure: 22.2 bar
  • Liquid fuel type: Distillate
  • Starting system: Starting motor

The auxiliary equipment of the gas turbine includes:

  1. Starting Equipment with an induction motor and torque converter coupled to the accessory gear.
  2. Turning Gear
  3. Lubricating Oil System with the following components:
    • Lube oil reservoir in the accessory base
    • Main lube oil pump (shaft driven from the accessory gear)
    • Auxiliary lube oil pump and emergency lube oil pump (motor driven)
    • Auxiliary seal oil pump and emergency seal oil pump (motor driven)
    • Pressure relief valve VR-1
    • Lube oil fluid heat exchangers
    • Lube oil filters
    • Bearing header pressure regulator VPR2-1
    • Mist eliminator
Shopping Cart